The 3-way zone valve is a multifunctional valve widely used in heating, ventilation and air conditioning (HVAC) systems, industrial automation and liquid control systems. Its main function is to control the flow direction of liquid or gas, and is usually used to adjust the distribution of media between multiple pipelines. The valve has three channels, one for the inlet and the other two for the outlet, which can be switched or mixed according to system requirements. In HVAC systems, 3 way zone valves are often used to distribute hot and cold water, and by adjusting the flow of different pipelines, energy efficiency is optimized and the control accuracy of the system is improved. It can also reduce energy consumption and improve operational efficiency.
3 way zone valve

 

DDF-K-H series ferrule electric valve is used to control the opening or closing of the end of the cooling and heating system pipe of the central air-conditioning system to achieve the purpose of controlling the room temperature. The control valve is driven by a one-way hysteresis synchronous motor and reset by a spring. The valve is normally closed when not working. When it is needed to work, the thermostat provides a valve opening signal to connect the driver to the AC power supply and open the valve, so that cold water or hot water enters the fan coil to provide cooling or heating for the room; when the room temperature reaches the set value of the thermostat, the thermostat cuts off the power of the electric valve, and the reset spring closes the valve, thereby cutting off the water flow into the fan coil. By closing and opening the valve, the room temperature is always kept within the temperature range set by the temperature control.

Product parameters

●Valve body material: forged brass
●Valve stem material: stainless steel
●Seal material: EPDM
●Working medium: cold/hot water
●Fluid temperature: 5~95℃
●Pressure: 1.6MPa
●Ambient temperature: 0~65℃ Maximum relative humidity is non-condensing
●Travel time: 11~15 seconds
●Motor torque: >800gf.cm

3 way zone valve
Technical Parameters

 

Ordering model Product model Valve type Diameter Connection method Kv value Maximum closing pressure difference
kPa
Dimensions
L W H
12613 DDF-K-H215.88*DFQ-HA1-220 2 port 15.88 welding 3 80 79 21 25
12614 DDF-K-H222.2DFQ-HA1-220 2 port 22.2 welding 3 80 89 21 25
12615 DDF-K-H228.6*DFQ-HA1-220 2 port 28.6 welding 3 60 92 21 25
Note: The above table is the commonly used recommended models, please consult for details.

 

 

Need to pay attention to these

 

 For high-rise buildings, pressure reducing valves should be used on the ground floor branches.
 The motor housing should prevent water drops from penetrating. Therefore, when the valve is installed, the driver must not be under the pipe.
 When the valve is installed on a vertical pipe, the motor housing must prevent water drops from penetrating.
 Manual operating lever: When the manual lever is slowly moved along the arrow direction and pressed into the gap to get stuck, the valve is in the normally open state. Whenever the current passes through the electric valve for the first time, the manual lever will be set to the automatic position again.
 If the driver is not pre-installed on the valve body, when it needs to be installed, first push the operating lever of the driver into the lower groove in the direction of the arrow, press the black button on the driver, put it on the valve body and release it, and then install it. If you need to disassemble, repeat the above operation.
 Note: The direction of water flow should be consistent with the direction of the arrow on the valve body; when installing, the driver must not be used as a fulcrum for force.

 

 

FAQ

 

Q1.What is the main function of a 3 way zone valve?
Its main function is to control the flow direction of liquid or gas, and is usually used to adjust the distribution of media between multiple pipelines.

 

Q2.What is the difference between a 3-way valve and a 2-way valve?
A 3-way valve has three channels, which can switch or mix the media, while a 2-way valve has only two channels and is usually used for switching control of a single path.

 

Q3.What do zone valves do?
A zone valve is a special type of valve used to control the flow of water or steam in a hydronic heating or cooling system. Such systems are often divided into zones for efficiency and occupant comfort.

 

Q4.What do th and tr on a zone valve stand for?
TH – The 24v hot leg sends a request for heat from the thermostat (R+W closed) to the gas valve (TH terminal) to open the solenoid valve, allowing gas to flow. This assumes the transformer is good and the high limit is closed. TR – The 24v common/return side of the transformer.

 

Q5.What is the working principle of a 3 way zone valve?
By controlling the rotation or movement of the valve core, the flow path of the fluid between different channels is changed to achieve flow regulation or distribution.

 

 