Products
Flange Type Globe Valve

Flange Type Globe Valve

DDF-S-J series threaded cast iron valves can adjust the flow of cold and hot water when equipped with DFQ-J series motor drive control devices. Flange type globe valve is widely used in liquid control in central air conditioning, heating, water treatment, industrial processing and other systems.
Flange type globe valve

●Valve core: stainless steel 06Cr19Ni10 (two-way), HPb59-1 (three-way)
●Valve stem seal: four-layer V-type and O-type combined nitrile rubber seal, polytetrafluoroethylene sealing sleeve
●Valve stem: stainless steel 06Cr19Ni10
●Valve body, valve cover material: HT250
●Nominal pressure (PN): 1.6MPa
●Working medium: water, fluid temperature 5~95℃
●Valve leakage: ≤0.03%KV
●Flange standard: GB/T 17241.6 PN16

IMG974343

 

Order code Product Model Valve type DN Connection Bolt size Kv value Stroke Dimensions

Maximum closing pressure difference

[kPa]

L d D H H1
12664 DDF-S-J-232 2 way 32 Flange 4×M16 21 20 180 ∅100 ∅135 125 108 600 --------- ---------
12665 DDF-S-J-240 2 way 40 Flange 4×M16 28 20 200 ∅l10 ∅145 128 119 500 --------- ---------
12483 DDF-S-J-250 2 way 50 Flange 4×M16 34 20 230 ∅125 ∅165 128 135 350 --------- ---------
12484 DDF-S-J-265 2 way 65 Flange 4×M16 54 20 290 ∅145 ∅185 140 165 250 --------- ---------
12485 DDF-S-J-280 2 way 80 Flange 8×M16 67 20 310 ∅160 ∅200 147 180 200 --------- ---------
12486 DDF-S-J-2100 2 way 100 Flange 8×M16 120 40 350 ∅180 ∅220 191 200 --------- 300 500
12487 DDF-S-J-2125 2 way 125 Flange 8×M16 180 40 400 ∅210 ∅250 205 230 --------- 200 350
12488 DDF-S-J-2150 2 way 150 Flange 8×M20 256 40 480 ∅240 ∅285 221 270 --------- 150 200
12666 DDF-S-J-2200 2 way 200 Flange 12×M20 330 40 600 ∅295 ∅340 254 329 --------- --------- 150
12667 DDF-S-J-332 3 way 32 Flange 4xM16 21 20 180 ∅100 ∅135 125 90 600 --------- ---------
12668 DDF-S-J-340 3 way 40 Flange 4×M16 28 20 200 ∅l10 ∅145 128 100 500 --------- ---------
12489 DDF-S-J-350 3 way 50 Flange 4×M16 34 20 230 ∅l25 ∅165 128 115 250 --------- ---------
12490 DDF-S-J-365 3 way 65 Flange 4×M16 54 20 290 ∅145 ∅185 140 145 200 --------- ---------
12491 DDF-S-J-380 3 way 80 Flange 8×M16 67 20 310 ∅160 ∅200 147 155 150 --------- ---------
12492 DDF-S-J-3100 3 way 100 Flange 8×M16 120 40 350 ∅180 ∅220 191 175 --------- 250 350
12493 DDF-S-J-3125 3 way 125 Flange 8×M16 180 40 400 ∅210 ∅250 205 200 --------- 200 250
12494 DDF-S-J-3150 3 way 150 Flange 8×M20 256 40 480 ∅240 ∅285 221 240 --------- --------- 200
12669 DDF-S-J-3200 3 way 200 Flange 12×M20 330 40 600 ∅295 ∅340 254 300 --------- --------- 150

 

 

Installation Instructions

 

DDF-S-J

 This series of valves is compatible with Johnson actuators.
 The valve stem moves downwards in the direction of valve opening.
 Before installing the valve, ensure that the pipe is clean and free of scale, metal flakes and other debris left during welding.
 The pipe must be concentric and free of vibration when connected to the valve body, and the water flow direction should be consistent with that marked on the valve body.
 When the actuator is installed vertically on the valve body, avoid installing the actuator under the valve, and leave enough space for daily maintenance (such as disassembling the actuator).
 When maintaining the valve, the power supply must be cut off or isolated, and the water system should not be under pressure.

 

 

FAQ

 

 

1.What is a flanged stop valve?

A flanged stop valve is a valve that opens or closes the fluid by rotating the valve stem. The valve body has flanges at both ends for flange connection with the pipeline system and is widely used in industrial pipelines.

 

2.What is the working principle of a flange type globe valve?

The flanged stop valve moves the valve stem up and down to make the valve disc in close contact or disengage from the valve seat, thereby achieving the shutoff or opening of the fluid. It is usually used to fully open or close, rather than to adjust the flow.

 

3.How does a flange type globe valve ensure good sealing?

The sealing is achieved by the precise contact between the valve disc and the valve seat. Usually, the sealing surface is specially treated (such as hardening or plating) to improve wear resistance and corrosion resistance, ensuring that it still has a good sealing effect after long-term use.

 

4.How to perform daily maintenance on flange globe valves?

Regularly check the wear of the sealing surface, lubricate the threaded part of the valve stem, ensure that the flange connection is tight and leak-free, and regularly remove internal impurities to maintain its normal operation.

 

5.How to judge the open or closed state of a flanged stop valve?

It can be judged by observing the position of the valve stem. When the valve stem is in the rising position, it means the valve is open; when the valve stem is fully lowered, it means the valve is closed.

 

 

Hot Tags: flange type globe valve, China flange type globe valve manufacturers, suppliers, factory, Electric 3 Way Valve, Digital Thermostat For Home, 3 8 Ball Valve, R22 Gauges, R1234yf Refrigerant Gauges, 3 Inch Electric Ball Valve